gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Fuel Line Coupler > < Procedures|Page 12120
Page 11
background image

1. Ensure that the CPA retainer is pulled out 1 click.
2. Connect the electrical connectors to their corresponding injectors.
3. Push the CPA retainer in 1 click.
4. Ensure that the connector is secured.

28. Connect the engine wiring harness electrical connector (4) to the MAP sensor.
29. Connect the engine wiring harness electrical connector (3) to the generator.
30. Connect the engine wiring harness electrical connector (2) to the EVAP purge solenoid.
31. Install the engine wiring harness bracket nut (1).

Tighten the nut to 5 N.m (44 lb in).

32. Connect the negative battery cable.
33. Use the following procedure in order to inspect for leaks:

1. Turn the ignition ON, with the engine OFF for 2 seconds.
2. Turn the ignition OFF for 10 seconds.
3. Turn the ignition ON, with the engine OFF.
4. Inspect for leaks.

34. Install the air cleaner outlet duct.

Fuel Line Coupler > < Procedures|Page 12120