CAUTION: When you are deploying an inflator module for disposal, perform the deployment procedures in the order listed:

^

Wear safety glasses throughout the procedures.

^

Make sure the area around the inflator module is clear of all people and loose or flammable objects.

^

Short the deployment harness wires as instructed.

^

Connect the deployment harness to the inflator module before you connect it to the power source.

^

Connect the deployment harness to the power source to Immediately deploy the air bag.

Failure to follow the procedures in the order listed may result in personal injury.

22. Twist together one connector wire lead to one deployment wire. The connection must be mechanically secure (Figure 30-1).
23. Bend flat the twisted connection that you made in the previous step. Secure the connection by wrap- ping tightly with electrical tape. This will also

insulate the connection (Figure 30-2).

24. Twist together bend and tape the remaining connector wire lead to the remaining deployment wire (Figure 30-3).
25. Connect the deployment harness to the inflatable restraint I/P module, yellow 2-way connector.
26. Route the deployment harness out the passenger side of the vehicle (Figure 31).
27. Be sure to clear the inside of the vehicle and the area surrounding the vehicle of any people. Clear the vehicle of all loose or flammable objects.