Yukon Denali 2WD V8-6.0L Hybrid (2010)
1. Attach a lifting device (2 and 3) to the drive motor generator control module assembly at the three identified locations.
2. Lift the drive motor generator control module assembly into the vehicle.
Caution: Refer to Fastener Caution (See: Service Precautions/Vehicle Damage Warnings/Fastener Caution).
3. Remove the lifting device and install the ball studs (1). Tighten the ball studs to 10 Nm (89 lb in).
4. Install the drive motor generator control module assembly retainers (4) and mounting nuts (3). Tighten the mounting nuts to 9 Nm (80 lb in).
5. Install the APM ground strap (1) and APM ground strap nut (2). Tighten the nut to 9 Nm (80 lb in).