gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Drive Motor Generator Control Module Sight Shield Replacement|Page 3515 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 3513
Page 5
background image

5. Rotate the drive motor generator control module assembly onto the APM.
6. Clamp GE-48494 - adapter kit components (2, 3) to a coolant pipe.
7. Plug the remaining coolant pipe with the GE-48494 - adapter kit plug and clamp (1).
8. Apply 20 psi (138 kPa) pressure with J 24460-01 - pressure tester  (4).
9. Monitor the pressure tester gauge for 5 minutes and ensure that pressure remains at the specified value.

*

If the specified pressure cannot be maintained, disassemble the drive motor generator control module assembly and replace the coolant seal.

*

If pressure remains at the specified value, proceed to the next step.

10. Remove all GE-48494 - adapter kit components.

11. Remove the PIM cover retaining bolts (1).
12. Remove the PIM cover (2).

Caution:  Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit
board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.

Drive Motor Generator Control Module Sight Shield Replacement|Page 3515 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 3513