gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Drive Motor Generator Control Module Sight Shield Replacement|Page 3567 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 3565
Page 4
background image

1. Install new APM coolant seal (3).
2. Position the APM (2) onto the PIM ensuring the seals remain in place.

Caution:  Refer to Fastener Caution   (See: Service Precautions/Vehicle Damage Warnings/Fastener Caution).

3. Install the APM mounting fasteners (1). Tighten the mounting fasteners to 10 Nm (89 lb in).

Note:  Only use pre-mixed DEX-COOL(R) on the coolant pipe O-ring to aid in tube installation.

4. Install the drive motor generator power inverter coolant pipes unless a service replacement PIM is being installed:

1. Lubricate the new seals (6, 9) with pre-mixed DEX-COOL(R).
2. Install new seals (6, 9) onto the drive motor generator power inverter coolant pipes (5, 8).
3. Install the coolant pipes (5, 8) to the PIM assembly with bolts (4, 7). Tighten the fasteners to 5 Nm (44 lb in).

Drive Motor Generator Control Module Sight Shield Replacement|Page 3567 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 3565