gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Drive Motor Generator Control Module Sight Shield Replacement|Page 3569 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 3567
Page 6
background image

13. Install the HV dc APM terminal fasteners (1) utilizing a magnetic socket. Tighten the terminal fasteners to 9 Nm (80 lb in).

14. Install a new PIM cover seal (3).

Note:  DO NOT use excessively abrasive cleaning tools on the sealing surface. Hand sanding with wet 400 grit sandpaper or use of a hand scraper
is recommended.

15. Clean the sealing surface of the PIM cover as necessary.
16. Position the PIM cover (2) onto the PIM ensuring the seal remains in place.
17. Install the PIM cover fasteners (1). Tighten the fasteners to 5 Nm (44 lb in).
18. Install the drive motor generator control module. Refer to Drive Motor Generator Control Module Assembly Replacement   (See: Drive Motor

Generator Control Module Assembly Replacement).

Drive Motor Generator Control Module Sight Shield Replacement|Page 3569 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 3567