Page 2
background image

normal and the ignition circuit fuse is open, replace the IPC.

4. Ignition OFF, disconnect harness connector X1 at the ECM.
5. Ignition ON, verify the MIL is not illuminated.

‹› If the MIL is illuminated, test the MIL control circuit for a short to ground. If the circuit tests normal, replace the IPC.

6. Connect a 3 A fused jumper wire between the MIL control circuit terminal 12-X1 and ground. The MIL should illuminate.

‹› If the MIL does not illuminate, test the MIL control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace

the IPC.

7. If all circuits test normal, replace the ECM.

Repair Instructions

Perform the Diagnostic Repair Verification   (See: Testing and Inspection/Diagnostic Trouble Code Tests and Associated Procedures/Verification Tests
and Procedures) after completing the diagnostic procedure.

*

Instrument Cluster Replacement (Except Cadillac)   (See: Instrument Panel, Gauges and Warning Indicators/Instrument Cluster / Carrier/Service
and Repair/Instrument Cluster Replacement (Except Cadillac))Instrument Cluster Replacement (Cadillac)   (See: Instrument Panel, Gauges and
Warning Indicators/Instrument Cluster / Carrier/Service and Repair/Instrument Cluster Replacement (Cadillac))

*

Control Module References   (See: Testing and Inspection/Programming and Relearning) for ECM replacement, setup, and programming