gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Valve Rocker Arm Cover Replacement - Left Side|Page 2352 > < Valve Rocker Arm Cover Replacement - Left Side|Page 2350
Page 1
background image

Valve Cover: Service and Repair
Valve Rocker Arm Cover Replacement - Right Side

Valve Rocker Arm Cover Replacement - Right Side

Removal Procedure

Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal
Protection Equipment (PPE) and proper procedures must be followed. 

The High Voltage Disabling procedure will perform the following tasks:

*

Identify how to disable high voltage.

*

Identify how to test for the presence of high voltage.

*

Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must
be followed.

Failure to follow the procedures exactly as written may result in serious injury or death.

1. Disable the high voltage system. Refer to High Voltage Disabling   See: Hybrid Drive Systems/Service and Repair/Procedures/High Voltage

Disabling.

2. Remove the intake manifold cover. Refer to Upper Intake Manifold Sight Shield Replacement   See: Intake Manifold/Service and Repair/Upper

Intake Manifold Sight Shield Replacement.

3. Remove the generator control module 3 phase cable clip nut (1).
4. Remove the generator control module 3 phase cable clip from the engine bracket (2).
5. Reposition the generator control module 3 phase cables out of the way.

Valve Rocker Arm Cover Replacement - Left Side|Page 2352 > < Valve Rocker Arm Cover Replacement - Left Side|Page 2350