gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Exhaust Manifold Replacement - Left Side|Page 2866 > < Exhaust Manifold Replacement - Left Side|Page 2864
Page 3
background image

Installation Procedure

Note:  

*

Tighten the exhaust manifold bolts as specified in the service procedure. Improperly installed and/or leaking exhaust manifold gaskets may affect
vehicle emissions and/or On-Board Diagnostics (OBD) II system performance.

*

The cylinder head exhaust manifold bolt hole threads must be clean and free of debris or threadlocking material.

*

Do not apply sealant to the first 3 threads of the bolt.

Caution:  Refer to Fastener Caution   See: Service Precautions/Vehicle Damage Warnings/Fastener Caution.

1. If the exhaust manifold was replaced, position and install the exhaust manifold heat shield, and bolts to the exhaust manifold.

Tighten the bolts to 9 Nm (80 lb in).

2. Clean the threads of the exhaust manifold bolts.
3. Apply a 5 mm (0.2 in) wide band of threadlock GM P/N 12345493 (Canadian P/N 10953488), or equivalent to the threads of the exhaust manifold

Exhaust Manifold Replacement - Left Side|Page 2866 > < Exhaust Manifold Replacement - Left Side|Page 2864