1. Install the NEW fuel tank module seal onto the fuel tank.
2. Pull the vent lines in the fuel tank up as far as possible for ease of installation.
3. Position the fuel tank module part way into the fuel tank.
4. Connect the quick connect fittings (1) to the module cover. Refer to Plastic Collar Quick Connect Fitting Service   See: Fuel Line Coupler/Service

and Repair/Plastic Collar Quick Connect Fitting Service.

5. Install the fuel tank module into the fuel tank.
6. Place the lock ring into position.

Note:  Always replace the fuel module seal when installing the fuel module. Replace the lock ring if necessary. DO NOT apply any type of
lubrication in the seal groove.

Ensure the lock ring is installed with the correct side facing upward. A correctly installed lock ring will only turn in a clockwise direction.

7. Rotate the lock ring counterclockwise using the J 45722   until fully seated.
8. Connect the fuel and EVAP lines to the fuel tank module. Refer to Plastic Collar Quick Connect Fitting Service   See: Fuel Line Coupler/Service

and Repair/Plastic Collar Quick Connect Fitting Service.