Accord L4-1955cc 2.0L SOHC 2-bbl (1986)
A/C Thermostat: Testing and Inspection
A/C Thermostat Test
Dip the thermostat capillary tube into a pan filled with ice water, and check for continuity.
Cut-off: 1.5 - O.5 °C (35 - 33°F)
Cut-in: 2.5 - 5.0 °C (37 - 41°F)
-
If cut-off or cut-in temperature is too low or too high, replace the thermostat.
-
The cut-off and cut-in of the thermostat must not be gradual, but sudden.