11. Apply vacuum to the hose.

It should not hold vacuum.

-

If it holds vacuum, turn the ignition switch OFF. Disconnect the 6P connector, then attach the positive probe of the voltmeter to the
Black/Yellow terminal, and the negative probe to the Red/Green terminal. Turn the ignition switch ON.

-

If there is voltage, replace the solenoid valve and re-test.

-

If there is no voltage, attach the positive probe of the voltmeter to the Black/Yellow terminal, and the negative probe to body ground.

-

If there is no voltage, repair the open in the Black/Yellow wire between the solenoid valve and the No.1 fuse.

-

If there is voltage, repair the open in the Red/Green wire between the solenoid valve and the ECU.

Idle Speed Inspection

Idle Control Test 

1. Check the vacuum line for proper connection, cracks, blockage or disconnected hoses.
2. Disconnect the lower vacuum hose of the idle control solenoid valve from the air chamber and connect a vacuum gauge to the vacuum hose.

3. Start the engine and check for vacuum.

NOTE: Check within 10 seconds.

There should be vacuum.