Accord L4-2.2L SOHC VTEC (1994)
Mode Control Motor: Service and Repair
Fresh Air/Recirculation Actuator
1. Disconnect the 4P connector from the recirculation control motor.
2. Remove the two self-tapping screws, recirculation control motor and the flange collar.
3. Install in the reverse order of removal, and after installation, make sure the recirculation control motor runs smoothly.