2.
Pull the window run channel away from the metal window frame for about 150 mm (6 inches) both horizontally and vertically, as shown.
3.
Cut a 5 x 100 mm strip of EPT sealer 5T. Starting at the ribbed channel above the rectangular hole, apply the EPT sealer strip down to the corner
and then along the side as shown.
4.
Carefully reinstall the window run channel into the metal window frame. Run water to check for leaks. If the leak persists, pull the window run
channel out, and check the position of the EPT sealer.
PARTS INFORMATION
EPT Sealer 5T:
P/N 06991-SA5-000, H/C 2086650
NOTE:
The part listed above contains enough EPT sealer to repair 400 doors.
WARRANTY CLAIM INFORMATION
In warranty:
The normal warranty applies.
Out of warranty:
Any repair performed after warranty expiration may be eligible for goodwill consideration by the District Service Manager or your Zone Office. You
must request consideration, and get a decision, before starting work.
Failed part:
P/N 72235-SV4-003
H/C 4272266