honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Windows - Water Leaking From The Tops Of The Doors|Page 8099 > < Windows - Water Leaking From The Tops Of The Doors
Page 2
background image

2.

Pull the window run channel away from the metal window frame for about 150 mm (6 inches) both horizontally and vertically, as shown.

3.

Cut a 5 x 100 mm strip of EPT sealer 5T. Starting at the ribbed channel above the rectangular hole, apply the EPT sealer strip down to the corner
and then along the side as shown.

4.

Carefully reinstall the window run channel into the metal window frame. Run water to check for leaks. If the leak persists, pull the window run
channel out, and check the position of the EPT sealer.

PARTS INFORMATION

EPT Sealer 5T:
P/N 06991-SA5-000, H/C 2086650

NOTE:

The part listed above contains enough EPT sealer to repair 400 doors.

WARRANTY CLAIM INFORMATION

In warranty:
The normal warranty applies.

Out of warranty:
Any repair performed after warranty expiration may be eligible for goodwill consideration by the District Service Manager or your Zone Office. You
must request consideration, and get a decision, before starting work.

Failed part:

P/N 72235-SV4-003 
H/C 4272266