honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Climate Control|Page 775
Page 2
background image

10. Measure the voltage between the No.1 terminal of audio-HVAC display panel 22P connector and body ground.

Is there 5V or more?

YES - Go to step 11.

NO - Repair the open in the wire between the audio-HVAC display panel and the A/C pressure switch.

11. Turn the ignition switch off.

12. Measure the resistance between the No.9 and No.10 terminals of the audio-HVAC display panel 22P connector.

Is the resistance less than 24 kOhms?

YES - Go to step 13.

NO - Repair cause of high resistance in the evaporator temperature circuit.

13. Reconnect the audio-HVAC display panel 22P connector.
14. Turn the ignition switch ON (II).
15. Check the blower motor operation at several speeds.

Does the blower motor operate at all speeds?

YES - Check for loose wires or poor connections at the audio-HVAC display panel 22P connector and at the A/C pressure switch 2P connector. If
the connections are good, substitute a known-good audio-HVAC display panel and recheck. If the symptom/indication goes away, replace the
original front panel assembly.

NO - Repair the problem in the blower motor circuit.

16. Check for proper A/C system pressure.

Is the pressure within specifications?

YES - Replace the A/C pressure switch.

NO - Repair the A/C pressure problem.

Solar Sensor, HVAC > < Climate Control|Page 775