honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

MCM Reset|Page 2566 > < MCM Reset
Page 2
background image

2. Remove the harness holder (A), the MCM relay (B), and the clip (C).
3. Remove the bolts (D), disconnect ground bolt (E), and then raise the MCM (F).

4. Connect the backprobe adapters (A) to the stacking patch cords (B), and connect the cords to a digital multimeter.
5. Using the wire insulation as a guide for the contoured tip of the backprobe adapter, gently slide the tip into the connector from the wire side until it

touches the end of the wire terminal.

MCM Reset|Page 2566 > < MCM Reset