14. Install the heater core and the evaporator core in the reverse order of removal.

15. Install the heater unit in the reverse order of removal, and note these items:

-

Do not interchange the inlet and outlet heater hoses, and install the hose clamps securely.

-

Refill the cooling system with engine coolant See: Engine, Cooling and Exhaust/Cooling System/Coolant/Service and Repair.

-

Make sure that there is no coolant leakage.

-

Make sure that there is no air leakage.

16. Do the battery terminal reconnection procedure See: Starting and Charging/Battery/Service and Repair/Procedures.