Accord Coupe L4-2.2L SOHC (16 Valve) (1996)
5. Measure taper at the edges of each journal. The difference between measurements on each journal must not exceed the standard.
Journal Taper
Standard (New): 0.005 mm (0.0002 in)
6. Measure runout on the No.2 journal of each balancer shaft to make sure the balancer shafts are not bent.
Balancer Shaft Total Indicated Runout
Standard (New): 0.02 mm (0.001 in)
Service Limit: 0.03 mm (0.001 in)