Mode Control Motor: Testing and Inspection

1. Connect battery power to the No. 1 terminal, and ground the No. 2 and No. 4 terminals; the recirculation control motor should run smoothly.

CAUTION:  Never connect the battery in the opposite direction.

2. Disconnect the No. 2 or No. 4 terminals from ground; the recirculation control motor should stop at FRESH or RECIRCULATE.

NOTE:  Don't cycle the recirculation control motor for a long time.

3. If the recirculation control motor does not run in step 1, remove it, and check the recirculation control linkage and doors for smooth movement. If

the recirculation control linkage and doors move smoothly, replace the recirculation control motor.