Accord Coupe L4-2.2L SOHC (16 Valve) (1996)
Lock-Up Control Solenoid Valve A/B: Service and Repair
1. Remove the mounting bolts and lock-up control solenoid valve assembly.
NOTE: Be sure to remove or replace the lock-up control solenoid valves A and B as an assembly.
2. Check the lock-up control solenoid valve fluid passages for dust or dirt, and replace as an assembly, if necessary.
3. Clean the mounting surface and fluid passages of the lock-up control solenoid valve assembly, and install a new filter/gasket.
4. Check the connector for rust, dirt or oil, then reconnect the connector securely.