Accord EX Coupe L4-2156cc 2.2L SOHC (VTEC) MFI (1997)
Wire Harness Location
-
Remove the modulator unit cover, and remove the wire harness.
Connector Location
-
Check the numbers stamped on the set plate, and connect each connector of the new wire harness to the set plate of the corresponding number.
NOTE: Be sure that each connector is locked securely with the two locking tabs.
-
Install the modulator unit cover and modulator unit.
-
Check the ABS function using the ALB checker. See: Antilock Brakes / Traction Control Systems/Testing and Inspection/Initial Inspection and