honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Air Mix Control Motor|Page 8036 > < Air Mix Control Motor
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Fresh Air/Recirculation Actuator

1. Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor

from the blower unit.

2. Install in the reverse order of removal. After installation, make sure the recirculation control motor runs smoothly.

Air Mix Control Motor|Page 8036 > < Air Mix Control Motor