Air Door Actuator / Motor: Testing and Inspection
Recirculation Control Motor

1. Disconnect the 7P connector from the recirculation control motor.

Recirculation Control Motor

2. Connect battery power to the No.1 terminal, and ground the No.5 and No.7 terminals; the recirculation control motor should run smoothly. To

avoid damaging the recirculation control motor, do not reverse power and ground.

3. Disconnect the No.5 and No.7 terminals from ground; the recirculation control motor should stop at Fresh or Recirculate. Don't cycle the

recirculation control motor for a long time.

4. If the recirculation control motor does not run in step 2, remove it, then check the recirculation control linkage and doors for smooth movement. If

they move smoothly, replace the recirculation control motor.