honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

End Play|Page 2189 > < End Play|Page 2187
Page 1
background image

Camshaft: Specifications
Run Out

Camshaft Total Runout:

Standard (New): 0.03 mm (0.001 inch) maximum
Service Limit: 0.04 mm (0.002 inch)

End Play|Page 2189 > < End Play|Page 2187