honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Air Mix Control Motor Test|Page 5516 > < Air Mix Control Motor Test|Page 5514
Page 3
background image

NO - Repair the recirculation control linkage or doors.

Heating and Air Conditioning

Recirculation Control Motor Circuit Troubleshooting

1. Check the No.3 (7.5 A) fuse in the driver's under-dash fuse/relay box.

Is the fuse OK?

YES - Go to step 2.

NO - Replace the fuse, and recheck.

2. Disconnect the recirculation control motor 7P connector.
3. Turn the ignition switch ON (II).

4. Measure the voltage between the No.1 terminal of the recirculation control motor 7P connector and body ground.

Is there battery voltage?

YES - Go to step 5.

NO - Repair open in the wire between the No.3 fuse in the driver's under-dash fuse/relay box and the recirculation control motor.

5. Turn the ignition switch OFF.
6. Test the recirculation control motor.

Is the recirculation control motor OK?

YES - Go to step 7.

NO - Go to step 12.

7. Disconnect the heater control panel 22P connector.

8. Check for continuity between the No.1 and No.11 terminals of the heater control panel 22P connector and body ground individually.

Is there continuity?

Air Mix Control Motor Test|Page 5516 > < Air Mix Control Motor Test|Page 5514