Accord LX Sedan L4-2156cc 2.2L SOHC MFI (1997)
Crankshaft: Testing and Inspection
Out-of Round and Taper
OUT-OF ROUND TAPER RUNOUT
OUT-OF-ROUND
^
Measure out-of-round at the middle of each rod and main journal in two places.
^
The difference between measurements on each journal must not be more than the service limit.
-
Journal Out-of-Round:
^
Standard (New): 0.005 mm (0.0002 inch) max.
^
Service Limit: 0.006 mm (0.0002 inch)
TAPER
^
Measure taper at the edge of each rod and main journal.
^
The difference between measurements on each journal must not be more than the service limit.
-
Journal Taper:
^
Standard (New): 0.005 mm (0.0002 inch) max.
^
Service Limit: 0.006 mm (0.0002 inch)
RUNOUT
^
Measure runout on all main journals to make sure the crank is not bent.
^
The difference between measurements on each journal must not be more than the service limit.