Accord LX Sedan L4-2156cc 2.2L SOHC MFI (1997)
Compressor Clutch Diode HVAC: Testing and Inspection
Diode - Test
NOTE: The diode is designed to pass current in one direction while blocking it in the opposite direction. Use an analog ohmmeter or a digital ohmmeter
equipped with a diode tester.
Check for current flow in both directions between the A and B terminals; there should be current flow in only one direction.