Power Door Lock Control Module: Testing and Inspection
Without Keyless Entry

Control Unit Input Test (Without Keyless Entry)

1.  Remove the driver's door panel.
2.  Disconnect the 14-P connector from the control unit.
3.  Inspect the connector and socket terminals to be sure they are all making good contact.

^  If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
^  If the terminals look OK, make the following input tests at the connector.

If any test indicates a problem, find and correct the cause, then recheck the system.

If all the input tests prove OK, the control unit must be faulty; replace it.

Control Unit Input Test (Without Keyless Entry)

Disconnect the 14-P connector from the power door lock control unit.