4. Loosen the locknut, and turn the adjusting screw until the feeler gauge slides back and forth with a slight amount of drag.
5. Tighten the locknut and check clearance again. Repeat adjustment if necessary.
6. Rotate crankshaft 180° counterclockwise (Camshaft pulley turns 90°). The "UP" mark should be on the exhaust side. Adjust valves on No.3
cylinder.