Accord Sedan L4-2.2L SOHC (16 Valve) (1996)
A/C Diode: Testing and Inspection
NOTE: The diode is designed to pass current in one direction while blocking it in the opposite direction. Use an analog ohmmeter or a digital ohmmeter
equipped with a diode tester.
Check for current flow in both directions between the A and B terminals; there should be current flow in only one direction.