honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

With Keyless Entry|Page 32 > < With Keyless Entry|Page 30
Page 1
background image

Power Door Lock Control Module: Testing and Inspection
Without Keyless Entry

Control Unit Input Test (Without Keyless Entry)

1. Remove the driver's door panel (see section 20).
2. Disconnect the 14-P connector from the control unit.
3. Inspect the connector and socket terminals to be sure they are all making good contact.

^

If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.

^

If the terminals look OK, make the following input tests at the connector.
-

If any test indicates a problem, find and correct the cause, then recheck the system.

-

If all the input tests prove OK, the control unit must be faulty; replace it.

With Keyless Entry|Page 32 > < With Keyless Entry|Page 30