Accord Sedan V6-2.7L SOHC (24 Valve) (1996)
NOTE: When loosening the expansion valve nuts, use a second wrench to hold the expansion valve or evaporator pipe. Otherwise, they can be
damaged.
10. Assemble in the reverse order of disassembly. Make note of following items.
-
Replace the 0-rings with new ones at each fitting, and apply a thin coat of refrigerant oil ((Sanden SP-10, Part No. 38899-P13-A01) before
installing them.
NOTE: Be sure to use the right 0-rings for HFC-134a (R-134a) to avoid leakage.
-
Install the expansion valve capillary tube with the capillary tube in contact with the suction line directly, and wrap it with tape.
-
Reinstall the A/C thermostat sensor to its original location.
11. Install in the reverse order of removal. Make note of the following items.
-
If you're installing a new evaporator, add refrigerant oil.
-
Replace the 0-rings with new ones at each fitting, and apply a thin coat refrigerant oil before installing them.
-
Apply sealant to the grommets.
-
Make sure that there is no air leakage.
-
Charge the system, and test its performance.