Accord Sedan V6-2.7L SOHC (24 Valve) (1996)
Starter Relay: Testing and Inspection
Mitsuba Starters
1. Remove and disconnect starter relay.
Fig. 10 Starter Relay Terminal Locations
2. Apply battery voltage to C and D terminals of relay, Fig. 10.
3. Check continuity between A and B terminals of relay. Continuity should exist.
4. Disconnect battery voltage. There should be no continuity between A and B terminals of relay.
5. If relay does not operate as specified, replace relay.