Accord Wagon EX L4-2156cc 2.2L SOHC (VTEC) MFI (1997)
6. Check whether the brake fluid level in the reservoir is at the MAX (upper) level. If level is low, add fresh fluid until the reservoir is refilled to the
MAX (upper) level.
7. Perform brake bleeding procedures. See: System Bleed
8. Perform ABS sunctional checks using the ALB checker. See: Antilock Brakes / Traction Control Systems/Testing and Inspection/Initial Inspection
and Diagnostic Overview
Reservoir Removal and Installation
1. Drain the brake fluid completely from the reservoir.
2. Remove the modulator unit from the vehicle. See: Removal and Installation
Reservoir Location
3. Remove the reservoir from the modulator unit.
4. Install the reservoir in the reverse order of removal.
5. Fill the reservoir to the MAX (upper) level with fresh brake fluid.
6. Install modulator unit. See: Removal and Installation
7. Bleed system. See: System Bleed
NOTE: After installing the modulator unit and bleeding the brakes, start the engine and make sure that the ABS indicator light goes off.
Wire Harness Removal and Installation
-
Remove the modulator unit from the vehicle. See: Removal and Installation