Civic L4-1.3L Hybrid (2008)
7. Disconnect the auxiliary electric water pump connector (A).
8. Attach a length of clear drain tube (A) to the bleed screw (B) under the servo unit (C), and loosen the bleed screw.
NOTE: Turn the bleed screw about 180°.
9. Turn the ignition switch to ON (II).
NOTE: Do not operate the pump motor for more than 110 seconds or it may be damaged.
10. When the brake fluid is drained out, tighten the bleed screw, then turn the ignition switch to LOCK (0).
NOTE: After draining the brake fluid from the servo unit and the power unit, the sound of the power unit function changes.
11. Install all removed parts and reconnect all connectors.