honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Refrigerant|Specifications > < A/C - Refrigerant Leak Detection|Page 6858
Page 4
background image

Low ambient light conditions (a dark work area) will aid in locating the leak.

NOTE:

Not all UV lamps work well with all types of fluorescent dye. Use only the lamp provided in the kit to inspect for leaks.

(c)

Inspect the entire system. Be sure to check these locations:

^

damaged and corroded areas

^

fittings

^

hose-to-line couplings

^

refrigerant controls

^

service ports

^

brazed or welded areas

^

areas near attachment points

(d)

Check for evaporator leaks by illuminating the evaporator drain tube area with the UV lamp and glasses.

(e)

After repairing a leak, remove any fluorescent residue using the GLO-AWAY dye cleaner from the kit and hot water (follow the instructions
on the bottle).

Disclaimer