Canister Vent Valve: Service and Repair

EVAP Canister Vent Shut Valve Replacement

1. Remove the EVAP canister.
2. Remove the cap (A).

3. Remove the EVAP canister vent shut valve (B).
4. Install the parts in the reverse order of removal with new O-rings (C) and new cap.

NOTE:  Do not coat the O-ring with oil.