honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Restraints - Occupant Detection System Initialization|Page 936 > < Restraints - Occupant Detection System Initialization
Page 2
background image

5.

Select the Diagnostic System icon to run the HDS

6.

Select the SCS icon.

7.

On the next screen, select YES to short the SCS line. After the line is shorted, the odometer flashes no.

8.

Connect the SCS service connector to the 2P memory erase signal (MES) connector. Do not use a jumper wire.

9.

Turn the ignition switch to ON (II).

10.

After turning the ignition switch to ON (II), the SRS indicator comes on for 6 seconds and then goes off. Within 4 seconds after the indicator goes
off, disconnect the SCS service connector from the MES connector.

11.

Within 4 seconds after the SRS indicator comes on again, reconnect the SCS service connector to the MES connector.

12.

Within 4 seconds after the SRS indicator goes off, disconnect the SCS service connector from the MES connector.

13.

Watch the SRS indicator:

^

If the SRS indicator blinks twice and then goes off, the ODS unit is initialized. Go to ODS UNIT CALIBRATION WITH MANUAL MODE.

^

If the SRS indicator blinks twice and then stays on, the ODS unit is initialized, but there are SRS DTCs that need to be cleared. Go to step 14.

^

If the SRS indicator stays on (does not blink), the ODS unit is not initialized. Repeat steps 3 thru 13. If after three attempts you cannot
initialize the ODS unit, refer to symptom troubleshooting in the service manual.

14.

Turn the ignition switch to LOCK (0).

15.

Disconnect the HDS.

16.

Connect the SCS service connector to the MES connector. Do not use a jumper wire.

Restraints - Occupant Detection System Initialization|Page 936 > < Restraints - Occupant Detection System Initialization