honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Electrical - GR8 Battery Diagnostic Station Update Info.|Page 5402 > < Electrical - GR8 Battery Diagnostic Station Update Info.|Page 5400
Page 2
background image

For more information about documenting the scheduled battery checks, refer to Service Bulletin 89-003, Battery Maintenance at Dealers.

ED-18 Battery Analyzer:

^

Check the condition of the battery and its state-of-charge:

-

When the vehicle arrives at your dealership

-

During the PDI

-

During scheduled battery maintenance while the vehicle is in storage

-

Before final delivery to the customer

NOTE: 

Keep a printout of every battery test. Your warranty claim may be rejected unless you show that the battery was properly maintained.

GR8 Battery Diagnostic Station:

^

Properly charge and diagnose the battery when indicated by the ED-18

^

Smart, fast, and safe battery charging

^

Power supply mode maintains proper voltage during extended vehicle service, such as updating the PCM

^

Jump start mode supplies up to 250 amps

Customer Scheduled Maintenance

ED-18 Battery Analyzer:

^

Check the condition of the battery and its state-of-charge when a vehicle comes in for scheduled maintenance.

GR8 Battery Diagnostic Station:

^

Properly charge and diagnose the battery when indicated by the ED-18

^

Smart, fast, and safe battery charging

^

Power supply mode maintains proper voltage during extended vehicle service, such as updating the PCM

ED-18 Battery Analyzer and GR8 Battery Diagnostic Station:

^ When the ED-18 or GR8 displays Replace Battery or Bad Cell Replace, it provides a 10-digit code that must be included with the warranty

claim. See WARRANTY COVERAGE for more information.

Used Vehicle Sale

ED-18 Battery Analyzer:

^

Check the condition of the battery and its state-of-charge:

-

During vehicle inspection

-

During scheduled battery maintenance when the vehicle is in storage

-

Before final delivery to the customer GR8 Battery Diagnostic Station:

^

Properly charge and diagnose the battery when indicated by the ED-18

^

Smart, fast, and safe battery charging

^

Power supply mode maintains proper voltage during extended vehicle service, such as updating the PCM

^

Jump start mode supplies up to 250 amps.