Pressure Regulating Solenoid: Testing and Inspection
CVT Drive Pulley Pressure Control Valve Solenoid Test

CVT Drive Pulley Pressure Control Valve Solenoid Test

1. Remove the air cleaner assembly and the intake air duct.
2. Disconnect the solenoid harness connector.

3. Measure the CVT drive pulley pressure control valve solenoid resistance between solenoid harness connector terminals No. 3 and No. 7.

Standard: 3.8-6.8 Ohms

4. If the resistance is out of standard, check for open or short in the solenoid harness. If the wires are OK, replace the CVT drive pulley pressure

control valve.

5. Connect a jumper wire from the battery positive terminal to solenoid harness connector terminal No. 3, and connect another jumper wire from the

battery negative terminal to terminal No. 7. A clicking sound should be heard.

6. If no sound is heard, remove the CVT drive pulley pressure control valve, and clean it, then recheck. Replace the CVT drive pulley pressure

control valve if a problem recurs.

CVT Drive Pulley Pressure Control Valve Solenoid Test|Page 4633 > < Pressure Regulating Solenoid, CVT|Diagrams