Heater Control Panel: Service and Repair
Recirculation Control Motor Replacement

Recirculation Control Motor Replacement

1.  Disconnect the 4P connector from the recirculation control motor and remove the wire harness holder.
2.  Remove the two screws, the recirculation control motor and flange collar.
3.  Install in the reverse order of removal. After installation, make sure the recirculation control motor operates smoothly.