Starter Solenoid: Testing and Inspection
Nippondenso Starters

Fig. 10  Starter Motor Terminal Locations

1.

Check hold in coil for continuity between S terminal and ground as shown in Fig. 10. Continuity should exist.

2.

Check pull in coil for continuity between S and M terminals. Continuity should exist.

3.

If solenoid does not operate as specified, replace solenoid.