honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Technician Safety Information|Page 8855 > < Technician Safety Information|Page 8853
Page 2
background image

-

Never perform electrical inspections to the airbags, such as measuring resistance.

-

Do not position yourself in front of the airbag assembly during removal, inspection, or replacement.

-

Refer to the scrapping procedures for disposal of the damaged airbag.

General Precautions

General Precautions

Please read the following precautions carefully before performing the airbag system service. Observe the instructions described or the airbags could
accidentally deploy and cause damage or injuries.

Except when performing electrical inspections, always turn the ignition switch OFF and disconnect the negative cable from the battery, and wait at least 
three minutes before beginning work.

NOTE:  The contents in the memory is not erased even if the ignition switch is turned OFF or the battery cables are disconnected from the battery.

Use the replacement parts which are manufactured to the same standards as the original parts and quality. Do not install used SRS parts from another
vehicle. Use only new parts when making SRS repairs.

Carefully inspect any SRS part before you install it. Do not install any part that shows signs of being dropped or improperly handled, such as dents,
cracks or deformation.

Before removing any of the SRS parts (including the disconnection of the connectors), always disconnect the SRS connector.

Use only a digital multimeter to check the system. If it is not a Honda multimeter, make sure its output is 10 mA (0.01 A) or less when switched to the
lowest value in the ohmmeter range. A tester with a higher output could cause accidental deployment and possible injury.

Do not put objects on the front passenger's airbag.

The original radio has a coded theft protection circuit. Be sure to get the customer's radio code before disconnecting the battery cable.

Precautions For Electrical Inspections

Precautions For Electrical Inspections

When using electrical test equipment, insert the probe of the tester into the wire side of the connector. Do not insert the probe of the tester into the
terminal side of the connector, and do not tamper with the connector.

Technician Safety Information|Page 8855 > < Technician Safety Information|Page 8853