Shift Interlock Solenoid: Testing and Inspection

Shift Lock Solenoid Test

1. Remove the center console panel and center console.

2. Disconnect the shift lock solenoid connector (2P).
3. Connect the No. 1 terminal of the shift lock solenoid connector (2P) to the battery positive terminal, and connect the No. 2 terminal to the battery

negative terminal.

4. Check that the shift lever can be moved from the P position. Release the battery terminals from the shift lock solenoid connector. Move the shift

lever back to the P position, and make sure it locks.

NOTE:  Do not connect power to the No. 2 terminal (reverse polarity) or you will damage the diode inside the solenoid.

5. Check that the shift lock releases when the shift lock release is pushed, and check that it locks when the shift lock release is released.
6. If the shift lock solenoid does not work properly, replace it.