Installation Instructions

1.

Install the number 78 jet in the choke opener vacuum hose.

Installation Instructions

2.

Remove hoses number 27 and 28 from the vacuum manifold at emission control box number 1. Fit a 1-1/2" length of vacuum hose on each end of
the "U" tube, then fit the "U" tube and hoses on the vacuum manifold.

3.

Cut vacuum hose number 2 in half and install the check valve in it.

Installation Instructions

4.

Apply the new vacuum hose routing label to the underside of the hood, right on top of the old label; clean any dirt and grease off the old label first.
Make sure you install the correct label (green for California cars, black for others), then destroy the remaining label.

Steps 5 through 16 apply to only the 1.5 Civic.

5.

Remove the distributor cap and seal, then remove the distributor and clamp it in a vise.

RELUCTOR

6.

Remove the rotor, then evenly pry off the reluctor with two screwdrivers.

(Note which side faces up. The reluctor must be reinstalled the same way later.)

7.

Remove the vacuum advance diaphragm (2 screws).