Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

1. Remove the A/C thermostat.
2. Connect battery power to the No.3 terminal, ground the No.2 terminal, and connect a test light between the No.1 and No.3 terminals.

NOTE:  Use a 12 V3W - 18W test light.

3. Dip the A/C thermostat into a cup filled with ice water, and check the test light.

Serpentine-type evaporator
The light should go off at 36 - 39 °F (2 - 4 °C) or less, and should come on at 39 - 41 °F (4 - 5 °C) or more.

Laminate-type evaporator
The light should go off at 39 - 43 °F (4 - 6 °C) or less, and should come on at 43 - 45 °F (6 - 7 °C) or more.

If the light doesn't come on and go off as specified, replace the A/C thermostat.