honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC > < Evaporator Temperature Sensor / Switch|Locations|Page 587
Page 1
background image

Evaporator Temperature Sensor / Switch: Testing and Inspection

1. Remove the A/C thermostat.
2. Connect battery power to the No.3 terminal, ground the No.2 terminal, and connect a test light between the No.1 and No.3 terminals.

NOTE:  Use a 12 V,3 W-18 W test light.

3. Dip the A/C thermostat into a cup filled with ice water, and check the test light.

Serpentine-type evaporator
The light should go off at 36 - 39°F (2 - 4°C) or less, and should come on at 39 - 41°F (4 - 5°C) or more.

Laminate-type evaporator
The light should go off at 39 - 43°F (4 - 5°C) or less, and should come on at 43 - 45°F (6 - 7°C) or more.

If the light doesn't come on and go off as specified, replace the A/C thermostat.

Refrigerant Pressure Sensor / Switch, HVAC > < Evaporator Temperature Sensor / Switch|Locations|Page 587