Civic EX Sedan L4-1668cc 1.7L SOHC (VTEC) MFI (2001)
Daytime Running Lamp Relay: Testing and Inspection
Power Relay Test
Use this chart to identify the type of relay, then do the test listed for it.
NOTE: See the turn signal/hazard relay input test.
Normally-open type A:
Check for continuity between the terminals.
-
There should be continuity between the No.1 and No.2 terminals when power and ground are connected to the No.3 and No.4 terminals.
-
There should be no continuity between the No.1 and No.2 terminals when power is disconnected.