High Pressure Safety Valve HVAC: Service and Repair
SANDEN

1. Remove the relief valve and the O-ring.

NOTE:
-

Do not let the compressor oil run out.

-

Make sure that no foreign matter enters the system.

2. Clean the mating surfaces.
3. Replace the O-ring with a new one at the relief valve, and apply a thin coat of refrigerant oil before installing it.

NOTE:
-

To avoid contamination, do not return the oil to the container once dispensed, and never mix it with other refrigerant oils.

-

Immediately after using the oil, replace the cap on the container, and seal it to avoid moisture absorption.

-

Do not spill the refrigerant oil on the vehicle; it may damage the paint; if the refrigerant oil contacts the paint, wash it off immediately.

4. Install and tighten the relief valve.
5. Charge the system and test its performance.