3.

Connect the appropriate fittings to the ATF cooler inlet and outlet lines. Connect the red hose to the cooler outlet line (the line going to the
external filter). Connect the blue hose to the cooler inlet line.

4.

Connect a shop air hose to the air purge valve.

NOTICE

The quick connect fitting has a one-way check valve to keep ATF from entering your shop's air system. Do not remove or replace the fitting.
Attach the coupler provided with the cooler cleaner to your shop air line if your coupler is not compatible.

5.

Flip the MOTOR toggle switch to ON, and let the pump run for 5 minutes. While the pump is running, open and close the air purge valve
periodically to cause agitation and improve the cleaning process.

6.

Flip the MOTOR toggle switch to OFF with the air purge valve open. Leave the air purge valve open for at least 15 seconds to purge the lines of
residual ATF.

7.

Disconnect the red and blue hoses from the ATF cooler, then connect the red hose to the cooler inlet line.

8.

Connect the blue hose to the cooler outlet line.

9.

Flip the MOTOR toggle switch to ON, and let the pump run for 5 minutes. While the pump is running, open and close the air purge valve
periodically.

10.

Flip the MOTOR toggle switch to OFF with the air purge valve open. Leave the air purge valve open for at least 15 seconds to purge the lines of
residual ATF.

11.

Disconnect the red and blue hoses from the ATF cooler lines. Connect the red and blue hoses to each other.

12.

Disconnect the shop air from the air purge valve. Disconnect and stow the coupler if used.

13.

Disconnect and stow the fittings from the ATF cooler inlet and outlet lines.

14.

Unplug the cooler cleaner from the 110 V outlet.

TOOL MAINTENANCE

Follow these instructions to keep the ATF cooler cleaner working properly:

*^ Replace the two magnetic nonbypass spin-on filters every 20 hours, based on hour meter reading. For more information on filter replacement, see the

January 2008 Honda ServiceNews article, Hour Meter Tells You When to Replace ATF Cooler Cleaner Filters.*

^

Fill the tank so the ATF is 4.5 inches from the top of the filler hole; do not overfill.

NOTE

If the fluid level is low, the red indicator above the HEAT toggle switch comes on and the tank heater will not work.

^

Replace the ATF in the tank when it looks dark or dirty.